Wall Stopend – Construction Joints Thin wall

In stop ends to thin walls (less than 900mm thick), the Hy-Rib will often be fixed to span vertically with the supports fitted horizontally. The concrete pressure diagram may not be uniform and will reduce near to the top, so that the distance between supports can increase in the top 3m of the pour.

Centre to Centre spacing of the supports from top of the wall and the approximate height of wall

Numbering of Supports Grade
2411
Grade
2611
Grade
2811
support spacing approx. wall height support spacing approx. wall height support spacing approx. wall height
mm mm  mm  mm  mm mm
1 > 2 650 note 5 575 note 5 550 note 5
2 > 3 575 note 5 525 note 5 500 note 5
3 > 4 525 1750 275 1575 450 1500
4 > 5 475 2225 425 2000 400 1900
5 > 6 425 2650 375 2375 375 2275
6 > 7 375 3025 325 2700 325 2600
7 > 8 375 3400 300 3000 275 2875
8 > 9 375 3775 300 3300 275 3150
9 > n 375 4150 300 3600 275 3425
Load in the supports Approx. 14.3 kN/m Approx. 11.4 kN/m Approx. 10.5 kN/m

 

Technical Support

Icon CaretAdditional Information

NOTES

The Hy-Rib is used in vertical sheets with the ribs pointing into the concrete. The value of support spacing is measured centre to centre of the vertical supports and is NOT the clear distance. The supports to the Hy-Rib are horizontal and are a minimum of 50mm wide. The approximate load per metre of the supporting members is given as a guide only. It is assumed that the Hy-Rib is continuous over at least three spans (i.e. over four horizontal supports). If this is not the case, refer to a designer for the increase in load on the supports.